How does the Rointe open window function work?

The Rointe open window function is invoked when the room temperature sensor detects a drop of 4ªC from the user-assigned temperature over a 30 minute period. Under these circumstances, the function will apply anti-frost mode (8ºC) for 2 hours, reverting to normal functionality at the end of this period, or when the user intervenes by pressing the ON/OFF button.